CMDCRC=NO, CMDTEO=NO, DATTEO=NO, CMDIDX=NO, CURLIM=NO, ACMD=NO, DATCRC=NO, CMDEND=NO, BOOTAE=0, DATEND=NO, ADMA=NO
Error Interrupt Status
| CMDTEO | Command Timeout Error 0 (NO): No Error 1 (YES): Timeout |
| CMDCRC | Command CRC Error 0 (NO): No Error 1 (YES): CRC Error Generated |
| CMDEND | Command End Bit Error 0 (NO): No error 1 (YES): End Bit Error Generated |
| CMDIDX | Command Index Error 0 (NO): No Error 1 (YES): Error |
| DATTEO | Data Timeout Error 0 (NO): No Error 1 (YES): Timeout |
| DATCRC | Data CRC Error 0 (NO): No Error 1 (YES): Error |
| DATEND | Data End Bit Error 0 (NO): No Error 1 (YES): Error |
| CURLIM | Current Limit Error 0 (NO): No Error 1 (YES): Power Fail |
| ACMD | Auto CMD Error 0 (NO): No Error 1 (YES): Error |
| ADMA | ADMA Error 0 (NO): No Error 1 (YES): Error |
| BOOTAE | Boot Acknowledge Error 0 (0): FIFO contains at least one byte 1 (1): FIFO is empty |